Operation Before Starting of Turbine
Before starting turbine
- Make sure oil reservoir is filled to teh normal level.
- Open all drain valves of the steam inlet line, and exhaust line.
- Supply lubricating oil into all bearings by operating a motor driven auxiliary lubrication oil pump.
- Open the cooling water valve to the oil cooler.
- Check the trip mechanism by pushing the trip nob and reset the trip and the emergency stop valve turning back the handle clockwise (Close).
- Make sure the governor is minimum speed setting.
- Open the exhaust valve after checking not to have drain on the exhaust fan. For condensing turbine, close the drain valve of the turbine casing.
- Open the stop valve on the main stem line after checking the drain at the inlet line.
- Open the stop valve, and adjust the pressure to 0,2 ~ 0,4kg/cm2G for condensing turbine.
- Make sure of no drains at the steam inlet line.