Starting Turbine
Starting
- Open the emergency stop valve slowly and close it when the turbine starts to ratate. If the turbine does not start, push the starting lever. Listen for any unusual noise.
- Open the emergency stop valve again and run the turbine at low speed, warming it up for about five minutes.
- After the warming up finished, open the emergency stop valve and bring the turbine gradually up to about 2,000rpm. Listen for any abnormal noise with a listening rod and check for vibration. If any abnormal moise are heard or vibration is excessive, the unit should be shut down and cause should be found.
- Close the drain valves when it becomes certain that the parts which they drain are free of water and the turbine is heated sufficiently to prevent additional accumulation of water.
- Make sure the motor of auxiliary oil pump is stopped automatically.